Inside SenSolve™

Your chamber, from more than one angle.

Conditions, electrical activity and cooling-system measurements belong together. Explore each dashboard view to see the information your research and service teams can work with.

SenSolve™ dashboard experience

Interactive example · Illustrative data · No live chamber connected

Conditions, with the context around them.

Temperature and humidity are the starting point. Setpoints, controller demand, room conditions and door activity help explain what you are seeing.

Chamber temperature40.1 °C
Setpoint40.0 °CController output−3%
HeatOffCoolOnAlarmOff
Relative humidity65.2 % RH
Setpoint65.0% RHController output95%
HumidifyOnDehumidifyOffAlarmOff

Chamber & room conditions

Psychrometric context

MeasurementChamberRoom
Temperature40.1 °C20.4 °C
Humidity65.2% RH46.8% RH
Dew point32.3 °C8.6 °C
Moisture33.5 g/m³8.3 g/m³

Door activity

Access alongside conditions

Openings in example period
1
Door state
Closed
Current time open
0 s

Review access events when investigating a change in temperature or humidity.

Controller & alarm context

Illustrative configured settings

Temperature deviation limits
±2.0 °C
Humidity deviation limits
±5.0% RH
Example alarm delay
900 s
View controller tuning example
LoopP (%)I (s)D (s)
Temperature1.024060.0
Humidity1.06512.4

These examples represent different monitoring configurations. Installed sensors, available views and functions vary by chamber. Readings and settings shown here are illustrative; they do not change chamber controls.

SenSolve™ / Illustrative dashboard

Chamber dashboard

CHAMBER AIRCHAMBER AIR 2THERMOELECTRIC 130.9 °CTHERMOELECTRIC 230.7 °CTHERMOELECTRIC 332.1 °CAIR IN40.0 °CAIR OUT38.4 °CΔT 1.6 °CAIR IN 223.9 °CAIR OUT 222.8 °CΔT 1.1 °C

Example readings. On a small screen, scroll across to inspect the full diagram.

Reading the whole picture

Start with a change. Follow the related signals.

Conditions and context

Review temperature and humidity with setpoints, room conditions and door events. Use history to see what happened before and after a change.

Components and demand

Compare controller demand with current and measured component temperatures. Bring those observations to an equipment investigation.

People and decisions

Give researchers, laboratory managers and service teams a common view. Monitoring supports investigation alongside chamber alarms, maintenance and operating procedures.

A reading or status alone does not establish a component failure. Your team interprets the measurements in the context of the equipment and the work inside it.

Discuss the views for your chamber

Talk to the right team.

Explore monitoring for your chambers, or get help with an existing SenSolve installation.

Sales & information

Discuss your equipment, sensor coverage and monitoring needs.

sales@sensolve.cominfo@sensolve.comRequest a demonstration →

SenSolve technical support

Get help with setup, account access and your monitoring dashboard.

support@sensolve.comFollow the setup guide →All contact options →

For Darwin Chambers equipment service:+1 (314) 534‑3111

    Chamber monitoring dashboards | SenSolve